Relationship between heart rate and precision performance in waterpolo throws
Eduardo Sáez Sáez de Villarreal
Citación
Sáez Sáez de Villarreal, E. (2005). Relationship between heart rate and precision performance in waterpolo throws. Apunts. Educación Física y Deportes, 82, 53-58.
Abstract
Relationship between Herat frequency and performance in throwing precision in waterpolo”. Purpose: To evaluate if the throwing precision from 4 meters at different heart rate intensities (180, 150 and 120) is altered and to what magnitude the effective loss in the throw to goal. Methodology: 12 waterpolo players from the Costa Rica’s national team, with 4 years of international experience. A waterpolo net (“sniper”) was used to assess throwing precision. Each player had 5 opportunities in each heart rate frequency and the number of successful shots was accounted for in percentages. This procedure was repeated in three different days. A one way ANOVA with repeated measures was done and a Post Hoc Tukey analysis to determine the statistical significant differences . Results: The statistical analysis indicated a significant difference between the three levels of throw that were tested. A continuous increase in precision as the heart rate decreased. Discussion: To go from (120 to 150) the precision decreased 20,53%, unlike when it passed from (150 to 180) there was a decreased from 33,94%. This results point out the importance of performing training where the throw with precision to the goal must be performed at intense heart pulsations and always close to the most possible real situation of match
Relationship between Herat frequency and performance in throwing precision in waterpolo”. Purpose: To evaluate if the throwing precision from 4 meters at different heart rate intensities (180, 150 and 120) is altered and to what magnitude the effective loss in the throw to goal. Methodology: 12 waterpolo players from the Costa Rica’s national team, with 4 years of international experience. A waterpolo net (“sniper”) was used to assess throwing precision. Each player had 5 opportunities in each heart rate frequency and the number of successful shots was accounted for in percentages. This procedure was repeated in three different days. A one way ANOVA with repeated measures was done and a Post Hoc Tukey analysis to determine the statistical significant differences . Results: The statistical analysis indicated a significant difference between the three levels of throw that were tested. A continuous increase in precision as the heart rate decreased. Discussion: To go from (120 to 150) the precision decreased 20,53%, unlike when it passed from (150 to 180) there was a decreased from 33,94%. This results point out the importance of performing training where the throw with precision to the goal must be performed at intense heart pulsations and always close to the most possible real situation of match.
ISSN: 1577-4015
Publicat: October 01, 2005
Editat per: © Generalitat de Catalunya Departament de la Presidència Institut Nacional d’Educació Física de Catalunya (INEFC)
© Copyright Generalitat de Catalunya (INEFC). Aquest article està disponible a la url https://www.revista-apunts.com/. Aquest treball està publicat sota una llicència Internacional de Creative Commons Reconeixement 4.0. Les imatges o qualsevol altre material de tercers d’aquest article estan incloses a la llicència Creative Commons de l’article, tret que s’indiqui el contrari a la línia de crèdit; si el material no s’inclou sota la llicència Creative Commons, els usuaris hauran d’obtenir el permís del titular de la llicència per reproduir el material. Per veure una còpia d’aquesta llicència, visiteu https://creativecommons.org/licenses/by-nc-nd/4.0/deed.en